Quantum Scalar 50 LTO-3HH User's Guide Page 168

  • Download
  • Add to my manuals
  • Print
  • Page
    / 290
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 167
Chapter 4 SNMP Trap List
Quantum Scalar 50 User’s Guide 144
XY-position fail The robotic hand has failed to
position the XY axis to a
predetermined physical location.
Critical Diagnostics
XY-safe to rotate fail The safe to rotate sensor used to
home the XY axis could not be
seen by the calibration routine.
Warning Diagnostics
Y-position fail (zone #) The robotic hand has failed to
position the XY axis to a
predetermined physical location.
Critical Diagnostics
Bad SCSI Sense Data A command sent to the drive
received bad sense data.
Warning Drive
Manager
Aborted any open
exchanges
Drive communications has failed. Informational Drive
Manager
ADT login failed The library failed to login and set
up communication to a drive.
Critical Drive
Manager
Bad reply received The drive did not return a valid
response.
Warning Drive
Manager
Login failed, too many
retries
The library could not initiate
communications with the drive.
Warning Drive
Manager
Login failed, no response Drive did not respond correctly to
the login command sequence.
Warning Drive
Manager
Unexpected login, not
handled or requested
The drive unexpectedly sent a
login request.
Informational Drive
Manager
ACI invalid Response The HP Gen 2 Drive returned an
invalid command response.
Warning
Critical
Drive
Manager
Command Id not
supported
This command is not supported
by the drive.
Critical Drive
Manager
Could not send adt
logout
Drive communications (possibly
due to hardware) is lost.
Critical Drive
Manager
Message Id not
supported
Command is not supported by the
drive.
Critical Drive
Manager
Event Detail Event Description Category Reported By