18 Gathering Systems Assurance Information
Verifying Power Requirements
This section provides the power requirements for the Pathlight VX.
Table 8
lists power requirements for the installation site.
Table 9
lists the power consumption of the Pathlight VX components.
Table 8 Power Requirements for the Installation Site
Power Requirement
Volts AC 100-240 VAC +/- 10%
a
(50-60 Hz)
a. The Volts AC requirement is 240 VAC in Australia.
Amps 36 Amps maximum @ 100 VAC
b
b. The Amps requirement is for the 11.5 TB Standard Configuration. Entry-Level Configurations will
generate fewer Amps and High-Performance Configurations will generate more Amps.
Pre-racked Pathlight VX Power Requirements 2 NEMA L6-30 connectors
Table 9 Power Consumption of Pathlight VX Components
Component Power Consumption in Watts Amperage @ 110 VAC
SNC 176 watts 1.6A
FC switch 170 watts 1.54A
MS ~ 300 watts ~ 2.7A
AX100SC
a
a. AX100SC power consumption is doubled in the 4.2 TB Pathlight VX-450 because this configuration contains 2
AX100SC enclosures; 2 x 250 watts (500 watts total).
250 watts ~ 2.8A
DPE
b
b. Power consumption is greater in a High-Performance Configuration with more DPEs. For example, the 24.1 TB
High Performance configuration contains 3 DPEs, so it consumes 3 x 578 watts (1734 watts total) for the DPEs.
578 watts 5.4A
DAE
c
c. Power consumption is greater in each 5.9 TB increment. For example, the 17.7 TB Standard Configuration
contains 3 DAEs, so it consumes 3 x 294 watts (882 watts total) for the DAEs.
294 watts 2.71A
Pathlight VX-450 (Total) ~ 896 watts ~ 8.64A
Pathlight VX-650 (Total) ~ 1518 watts ~ 13.95A