Chapter 4: Configuring the Library
Saving and Restoring the Library Configuration
Quantum Scalar i40 and Scalar i80 User’s Guide 101
Saving the Library
Configuration
It is recommended that you save the library configuration after
modifying a configurable item and before upgrading firmware. This
allows you to restore the most current settings if necessary.
This operation saves your current library configuration and library
firmware.
Save your library configuration when it is in a known working state. In
the event of a hardware failure, the saved configuration can be used to
restore the configuration after hardware repairs are made.
Before initiating a firmware upgrade, you should save the library
configuration. You then have the option to restore the configuration
after either a successful or an unsuccessful upgrade.
You can only save the configuration from the Web client.
Web Client
1 Select Tools > Save/Restore Configuration.
2 Select Save System Configuration.
3 Click Apply.
4 When the operation completes successfully, complete the next
screens to save the file to a known location.
Restoring the Library
Configuration
You can restore the library’s configurable items to a previous state using
a saved configuration file. If you updated the library firmware since last
saving the configuration, the library automatically restores the library
firmware to the version that was saved with the configuration.
You can also downgrade library firmware to an earlier version using the
Tools > Update Library Firmware command. Note that you will lose all
your current library configuration information except for network
settings, date and time, and license keys. You can restore the other
configurable items using a configuration file that was saved when the
earlier version of library firmware was installed on the library, or you can
reconfigure your library’s settings.
You can only restore the library configuration via the Web client.