Appendix A Loading Revised Firmware
Using Firmware Cartridges
Quantum DAT 160 User’s Guide 52
Using Firmware Cartridges 1
The following procedure describes how to upgrade the tape drive
firmware using a firmware upgrade tape cartridge. Firmware upgrade
cartridges are available only to qualified Quantum OEM customers.
Contact your sales representative for information.
1 Power on the host system with the DAT 160 drive installed.
2 Close all applications that might try to communicate with the drive
during the firmware upgrade procedure.
3 Insert the firmware upgrade cartridge. The drive automatically
recognizes the firmware upgrade cartridge and begins downloading
the firmware from the cartridge into DRAM. When the firmware has
been downloaded into DRAM, the drive ejects the firmware upgrade
cartridge and the drive LEDs blink in a progressive pattern. When the
blinking pattern stops, the firmware upgrade operation is complete.
4 It may be necessary to reboot the system to ensure that your backup
software application continues to recognize the tape drive.
Note: The firmware can also be upgraded from a host computer via
the SCSI connection using software available at
www.quantum.com.
Warning: Once the firmware upgrade cartridge is inserted into
the drive, no power interruption can occur while the
firmware is loading. Do not power off the drive. If a
power interruption occurs, the firmware may not be
loaded correctly and the drive may not operate
properly.
Do not power down the host system or disconnect
power to the drive until the drive LEDs stop flashing.
Otherwise, the drive may be rendered inoperative.