Pathlight VX User’s Guide 17
Starting Up and Shutting Down the Pathlight VX
Use the procedures in this section to start up and shut down the Pathlight VX (system software and
hardware components).
Starting Up the Pathlight VX
If the Pathlight VX rack has power distribution units (PDUs) or an equivalent mechanism, you can
switch on all components at the same time. If the Pathlight VX was pre-racked when it was installed,
then its rack contains PDUs.
If the Pathlight VX rack does not have PDUs or an equivalent mechanism, go to Step 1
.
1 If the Pathlight VX bezel is attached to the system, remove it.
a. Grasp both sides of the bezel near the top.
b. Pull evenly on both sides of the bezel until the mounting clips release on each side.
c. Store the bezel in a secure location.
2 Verify the status of the components' power buttons. Do one of the following:
If an FC switch is present, turn it on by placing each power button (on the front panel) in the on
position and then go to Step 3
.
If an FC switch is not present, go to Step 3
.
3 Turn on the SNC by plugging each utility module's power cord to an AC power source.
4 Turn on each RAID. If the system is a Pathlight VX-450, go to Step 5
. If the system is a Pathlight VX-
650, go to Step 6
.
5 On each AX100SC, verify that the power cable is plugged in the power receptacle and use a pen to
push in the power button for 1 second. Go to Step 10
on page 18.
6 On each DPE and DAE, determine whether the enclosure has power buttons.
7 Turn on each DAE in sequence (DAE A1, DAE A2, DAE A3, etc.).
If the back panel contains power buttons, place them in the on position.
If the back panel does not contain power buttons, plug each power supply/cooling module's power
cord in an AC power source.
8 Turn on each SPS by placing the power button (on the back panel) in the on position.
Note
Before you begin, note:
The SNC does not have power buttons. Each SNC uses either 1 or 2
power cords. Power to the SNC is controlled by plugging each power cord
in or out of an AC power source.
On DPEs or DAEs that do not have power buttons, power is controlled by
plugging each power cord in or out of an AC power source.
CAUTION
The SNC does not initialize until the MS is started up and fully booted
(after the Pathlight VX software starts). While the MS is starting up, the
LEDs on the FC blade(s) "racetrack" (blink on and off).