Cleaning Drives 5-21
September 2007
Eject a Cleaning Cartridge
This procedure describes how to eject a cleaning tape. For
more information, refer to Eject Clean Tape Dialog on page 4-58.
Step 1 From the operator panel Main Menu, select
Commands Insert/Eject Eject Clean Tape.
The Insert Clean Tape Dialog appears. See Figure 5-20.
Figure 5-20 Insert Clean Tape Dialog
Step 2 Enter the source Coord, Index, and Accept.
The Eject In Progress appears. See Figure 5-21.
Figure 5-21 Eject In Progress
Step 3 The cleaning cartridge is ejected to the first
available slot in the I/E station.
The Complete Dialog appears. See Figure 5-22.
Figure 5-22 Complete Dialog
Enter SOURCE
Coord: S 01 1< A 01
Index: ST 00001
Accept: N
Eject in progress
Source : 00001
Target : 00788
Requested command is
now complete.