Appendix C Automatic Drive Cleaning
Selection of Cleaning Mode
100 Quantum|ATL P3000 Series User’s Guide
Determining when a cleaning cartridge has used all 20 of its
available cleaning cycles
Moving used up cartridges to the load port
Automatic Drive
Cleaning Mode
3
Automatic drive cleaning is disabled by default. In automatic drive
cleaning mode the library is responsible for all cleaning functions
such as:
Detecting when a drive requires cleaning
Tracking and selecting cleaning cartridges
Moving a cleaning cartridge to the drive
Determining when a cleaning cartridge has used all 20 of its
available cleaning cycles
Moving used up cartridges to the load port
Selection of Cleaning Mode
3
The cleaning mode is selectable from the:
•Diagnostic software
•GUI
Mode Select command
The default cleaning mode is host-initiated. A Mode Select
command permanently changes the cleaning mode in the library’s
NVRAM, and is retained if the library power is cycled.
Diagnostic
Software
3
To change automatic cleaning mode from the diagnostic software
select
Config
:
Enable clean tape
- turns automatic cleaning mode on
Disable clean tape
- turns automatic cleaning mode off