Chapter 3 Media Changer Commands
Write Buffer Command (3Bh)
Quantum ATL SuperLoader Software Interface Guide 171
Write Buffer Command (3Bh) 3
The WRITE BUFFER command is used with READ BUFFER as a
diagnostic function and for downloading and updating microcode
(firmware).
Figure 90 Write Buffer
Descriptor
Bit
Byte7654 3210
0
Operation Code (3Bh)
1
Logical Unit Number Reserved Mode
2
Buffer ID
3 - 5
(MSB)
Buffer Offset
(LSB)
6 - 8
(MSB)
Transfer Length
(LSB)
9
Unused Reserved Flag Link